diff mbox series

[09/16] hwmon: (mr75203) add VM pre-scalar property for Moortec PVT controller

Message ID 20220816082757.11990-10-farbere@amazon.com
State New
Headers show
Series Variety of fixes and new features for mr75203 driver | expand

Commit Message

Farber, Eliav Aug. 16, 2022, 8:27 a.m. UTC
vm-pre-scalar-ch# is a per channel optional parameter that can be
used to normalzie the voltage output results.

Signed-off-by: Eliav Farber <farbere@amazon.com>
---
 .../devicetree/bindings/hwmon/moortec,mr75203.yaml        | 8 ++++++++
 1 file changed, 8 insertions(+)
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
index 6111b5069b3c..e2a55001eefc 100644
--- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
+++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
@@ -56,6 +56,12 @@  properties:
       A value of 0 means that the entire VM sensor is nou used.
     $ref: /schemas/types.yaml#definitions/uint8-array
 
+  vm-pre-scalar-ch#:
+    description:
+      vm-active-channels defines the pre-scalar per channel value
+      used to normalzie the voltage output results.
+    $ref: /schemas/types.yaml#definitions/uint32
+
 required:
   - compatible
   - reg
@@ -68,6 +74,7 @@  additionalProperties:
   - intel,vm-map
   - reset-control-skip
   - vm-active-channels
+  - vm-pre-scalar-ch#
 
 examples:
   - |
@@ -82,5 +89,6 @@  examples:
         clocks = <&osc0>;
         resets = <&rcu0 0x40 7>;
         vm-active-channels = [08 10 02];
+        vm-pre-scalar-ch5 = <2>;
         #thermal-sensor-cells = <1>;
     };