diff mbox series

[07/16] hwmon: (mr75203) add VM active channels property for Moortec PVT controller

Message ID 20220816082757.11990-8-farbere@amazon.com
State New
Headers show
Series Variety of fixes and new features for mr75203 driver | expand

Commit Message

Farber, Eliav Aug. 16, 2022, 8:27 a.m. UTC
Add optional "vm-active-channels" property to define the number of
active channels per VM.

Signed-off-by: Eliav Farber <farbere@amazon.com>
---
 .../devicetree/bindings/hwmon/moortec,mr75203.yaml       | 9 +++++++++
 1 file changed, 9 insertions(+)
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
index da9c3cdcb6f0..6111b5069b3c 100644
--- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
+++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml
@@ -49,6 +49,13 @@  properties:
       reset-control-skip bool property defines if obtaining a
       reference to a reset controller should be skipped.
 
+  vm-active-channels:
+    description:
+      vm-active-channels defines the number of channels per VM
+      that are actually used and are connected to some source.
+      A value of 0 means that the entire VM sensor is nou used.
+    $ref: /schemas/types.yaml#definitions/uint8-array
+
 required:
   - compatible
   - reg
@@ -60,6 +67,7 @@  required:
 additionalProperties:
   - intel,vm-map
   - reset-control-skip
+  - vm-active-channels
 
 examples:
   - |
@@ -73,5 +81,6 @@  examples:
         intel,vm-map = [03 01 04 ff ff];
         clocks = <&osc0>;
         resets = <&rcu0 0x40 7>;
+        vm-active-channels = [08 10 02];
         #thermal-sensor-cells = <1>;
     };