@@ -429,6 +429,8 @@ struct tegra_pmc {
struct irq_chip irq;
struct notifier_block clk_nb;
+
+ bool core_domain_state_synced;
};
static struct tegra_pmc *pmc = &(struct tegra_pmc) {
@@ -1303,6 +1305,11 @@ static int tegra_powergate_add(struct tegra_pmc *pmc, struct device_node *np)
return err;
}
+bool tegra_pmc_core_domain_state_synced(void)
+{
+ return pmc->core_domain_state_synced;
+}
+
static int
tegra_pmc_core_pd_set_performance_state(struct generic_pm_domain *genpd,
unsigned int level)
@@ -3792,6 +3799,21 @@ static const struct of_device_id tegra_pmc_match[] = {
{ }
};
+static void tegra_pmc_sync_state(struct device *dev)
+{
+ int err;
+
+ pmc->core_domain_state_synced = true;
+
+ /* this is a no-op if core regulator isn't used */
+ mutex_lock(&pmc->powergates_lock);
+ err = dev_pm_opp_sync_regulators(dev);
+ mutex_unlock(&pmc->powergates_lock);
+
+ if (err)
+ dev_err(dev, "failed to sync regulators: %d\n", err);
+}
+
static struct platform_driver tegra_pmc_driver = {
.driver = {
.name = "tegra-pmc",
@@ -3800,6 +3822,7 @@ static struct platform_driver tegra_pmc_driver = {
#if defined(CONFIG_PM_SLEEP) && defined(CONFIG_ARM)
.pm = &tegra_pmc_pm_ops,
#endif
+ .sync_state = tegra_pmc_sync_state,
},
.probe = tegra_pmc_probe,
};
@@ -231,11 +231,17 @@ static inline void tegra_pmc_enter_suspend_mode(enum tegra_suspend_mode mode)
#if defined(CONFIG_SOC_TEGRA_PMC) && defined(CONFIG_PM_SLEEP)
enum tegra_suspend_mode tegra_pmc_get_suspend_mode(void);
+bool tegra_pmc_core_domain_state_synced(void);
#else
static inline enum tegra_suspend_mode tegra_pmc_get_suspend_mode(void)
{
return TEGRA_SUSPEND_NONE;
}
+
+static inline bool tegra_pmc_core_domain_state_synced(void)
+{
+ return false;
+}
#endif
#endif /* __SOC_TEGRA_PMC_H__ */
Add driver state syncing that is invoked once all PMC consumers are attached and ready. The consumers are the power domain clients. The synchronization callback is invoked once all client drivers are probed, the driver core handles this for us. This callback informs PMC driver that all voltage votes are initialized by each PD client and it's safe to begin voltage scaling of the core power domain. Signed-off-by: Dmitry Osipenko <digetx@gmail.com> --- drivers/soc/tegra/pmc.c | 23 +++++++++++++++++++++++ include/soc/tegra/pmc.h | 6 ++++++ 2 files changed, 29 insertions(+)