diff mbox series

[5.8,167/255] hwmon: (gsc-hwmon) Scale temperature to millidegrees

Message ID 20200901151008.696784793@linuxfoundation.org
State New
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman Sept. 1, 2020, 3:10 p.m. UTC
From: Tim Harvey <tharvey@gateworks.com>

commit c1ae18d313e24bc7833e1749dd36dba5d47f259c upstream.

The GSC registers report temperature in decidegrees celcius so we
need to scale it to represent the hwmon sysfs API of millidegrees.

Cc: stable@vger.kernel.org
Fixes: 3bce5377ef66 ("hwmon: Add Gateworks System Controller support")
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Link: https://lore.kernel.org/r/1598548824-16898-1-git-send-email-tharvey@gateworks.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
 drivers/hwmon/gsc-hwmon.c |    1 +
 1 file changed, 1 insertion(+)
diff mbox series

Patch

--- a/drivers/hwmon/gsc-hwmon.c
+++ b/drivers/hwmon/gsc-hwmon.c
@@ -172,6 +172,7 @@  gsc_hwmon_read(struct device *dev, enum
 	case mode_temperature:
 		if (tmp > 0x8000)
 			tmp -= 0xffff;
+		tmp *= 100; /* convert to millidegrees celsius */
 		break;
 	case mode_voltage_raw:
 		tmp = clamp_val(tmp, 0, BIT(GSC_HWMON_RESOLUTION));