@@ -6564,8 +6564,11 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)
struct cpumask *pd_mask = perf_domain_span(pd);
unsigned long cpu_cap = arch_scale_cpu_capacity(cpumask_first(pd_mask));
unsigned long max_util = 0, sum_util = 0;
+ unsigned long _cpu_cap = cpu_cap;
int cpu;
+ _cpu_cap -= arch_scale_thermal_pressure(cpumask_first(pd_mask));
+
/*
* The capacity state of CPUs of the current rd can be driven by CPUs
* of another rd if they belong to the same pd. So, account for the
@@ -6601,8 +6604,10 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)
* is already enough to scale the EM reported power
* consumption at the (eventually clamped) cpu_capacity.
*/
- sum_util += effective_cpu_util(cpu, util_running, cpu_cap,
- ENERGY_UTIL, NULL);
+ cpu_util = effective_cpu_util(cpu, util_running, cpu_cap,
+ ENERGY_UTIL, NULL);
+
+ sum_util += min(cpu_util, _cpu_cap);
/*
* Performance domain frequency: utilization clamping
@@ -6613,7 +6618,7 @@ compute_energy(struct task_struct *p, int dst_cpu, struct perf_domain *pd)
*/
cpu_util = effective_cpu_util(cpu, util_freq, cpu_cap,
FREQUENCY_UTIL, tsk);
- max_util = max(max_util, cpu_util);
+ max_util = max(max_util, min(cpu_util, _cpu_cap));
}
return em_cpu_energy(pd->em_pd, max_util, sum_util);