@@ -2629,6 +2629,21 @@ static unsigned int serial8250_get_baud_rate(struct uart_port *port,
struct ktermios *old)
{
unsigned int tolerance = port->uartclk / 100;
+ unsigned int min;
+ unsigned int max;
+
+ /*
+ * Handle magic divisors for baud rates above baud_base on SMSC
+ * Super I/O chips. Enable custom rates of clk/4 and clk/8, but
+ * disable divisor values beyond 32767, which are unavailable.
+ */
+ if (port->flags & UPF_MAGIC_MULTIPLIER) {
+ min = port->uartclk / 16 / UART_DIV_MAX >> 1;
+ max = (port->uartclk + tolerance) / 4;
+ } else {
+ min = port->uartclk / 16 / UART_DIV_MAX;
+ max = (port->uartclk + tolerance) / 16;
+ }
/*
* Ask the core to calculate the divisor for us.
@@ -2636,9 +2651,7 @@ static unsigned int serial8250_get_baud_rate(struct uart_port *port,
* slower than nominal still match standard baud rates without
* causing transmission errors.
*/
- return uart_get_baud_rate(port, termios, old,
- port->uartclk / 16 / UART_DIV_MAX,
- (port->uartclk + tolerance) / 16);
+ return uart_get_baud_rate(port, termios, old, min, max);
}
/*