diff mbox series

[5.10,12/67] can: j1939: j1939_xtp_rx_dat_one(): fix rxtimer value between consecutive TP.DT to 750ms

Message ID 20210802134339.433892557@linuxfoundation.org
State Superseded
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman Aug. 2, 2021, 1:44 p.m. UTC
From: Zhang Changzhong <zhangchangzhong@huawei.com>

commit c6eea1c8bda56737752465a298dc6ce07d6b8ce3 upstream.

For receive side, the max time interval between two consecutive TP.DT
should be 750ms.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Link: https://lore.kernel.org/r/1625569210-47506-1-git-send-email-zhangchangzhong@huawei.com
Cc: linux-stable <stable@vger.kernel.org>
Signed-off-by: Zhang Changzhong <zhangchangzhong@huawei.com>
Acked-by: Oleksij Rempel <o.rempel@pengutronix.de>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
---
 net/can/j1939/transport.c |    2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox series

Patch

--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1869,7 +1869,7 @@  static void j1939_xtp_rx_dat_one(struct
 		if (!session->transmission)
 			j1939_tp_schedule_txtimer(session, 0);
 	} else {
-		j1939_tp_set_rxtimeout(session, 250);
+		j1939_tp_set_rxtimeout(session, 750);
 	}
 	session->last_cmd = 0xff;
 	consume_skb(se_skb);