diff mbox series

[v7,13/15] docs: coresight: Update documentation for CoreSight to cover CTI.

Message ID 20191230164441.28375-1-mike.leach@linaro.org
State New
Headers show
Series None | expand

Commit Message

Mike Leach Dec. 30, 2019, 4:44 p.m. UTC
Add new document covering CTI / CTM usage in CoreSight.

Add section in coresight.rst introducing CTI and CTM modules with link
to new document.

Signed-off-by: Mike Leach <mike.leach@linaro.org>
Reviewed-by: Suzuki K Poulose <suzuki.poulose@arm.com>
Reviewed-by: Mathieu Poirier <mathieu.poirier@linaro.org>
---
 .../trace/coresight/coresight-ect.rst         | 211 ++++++++++++++++++
 Documentation/trace/coresight/coresight.rst   |  13 ++
 2 files changed, 224 insertions(+)
 create mode 100644 Documentation/trace/coresight/coresight-ect.rst

Comments

Mike Leach Jan. 13, 2020, 9:26 p.m. UTC | #1
Thanks - these will be fixed in v8

Mike

On Mon, 30 Dec 2019 at 22:31, Randy Dunlap <rdunlap@infradead.org> wrote:
>
> Hi Mike,
>
> Just a couple of small nits below.
>
>
> On 12/30/19 8:44 AM, Mike Leach wrote:
> > Add new document covering CTI / CTM usage in CoreSight.
> >
> > Add section in coresight.rst introducing CTI and CTM modules with link
> > to new document.
> >
> > Signed-off-by: Mike Leach <mike.leach@linaro.org>
> > Reviewed-by: Suzuki K Poulose <suzuki.poulose@arm.com>
> > Reviewed-by: Mathieu Poirier <mathieu.poirier@linaro.org>
> > ---
> >  .../trace/coresight/coresight-ect.rst         | 211 ++++++++++++++++++
> >  Documentation/trace/coresight/coresight.rst   |  13 ++
> >  2 files changed, 224 insertions(+)
> >  create mode 100644 Documentation/trace/coresight/coresight-ect.rst
> >
> > diff --git a/Documentation/trace/coresight/coresight-ect.rst b/Documentation/trace/coresight/coresight-ect.rst
> > new file mode 100644
> > index 000000000000..3e06588f24fa
> > --- /dev/null
> > +++ b/Documentation/trace/coresight/coresight-ect.rst
> > @@ -0,0 +1,211 @@
> > +=============================================
> > +CoreSight Embedded Cross Trigger (CTI & CTM).
> > +=============================================
> > +
> > +    :Author:   Mike Leach <mike.leach@linaro.org>
> > +    :Date:     November 2019
> > +
> > +Hardware Description
> > +--------------------
> > +
> > +The CoreSight Cross Trigger Interface (CTI) is a hardware device that takes
> > +individual input and output hardware signals known as triggers to and from
> > +devices and interconnects them via the Cross Trigger Matrix (CTM) to other
> > +devices via numbered channels, in order to propagate events between devices.
> > +
> > +e.g.::
> > +
> > + 0000000  in_trigs  :::::::
> > + 0 C   0----------->:     :             +======>(other CTI channel IO)
> > + 0  P  0<-----------:     :             v
> > + 0   U 0  out_trigs :     : Channels  *****      :::::::
> > + 0000000            : CTI :<=========>*CTM*<====>: CTI :---+
> > + #######  in_trigs  :     : (id 0-3)  *****      :::::::   v
> > + # ETM #----------->:     :                         ^   #######
> > + #     #<-----------:     :                         +---# ETR #
> > + ####### out_trigs  :::::::                             #######
> > +
> > +The CTI driver enables the programming of the CTI to attach triggers to
> > +channels. When an input trigger becomes active, the attached channel will
> > +become active. Any output trigger attached to that channel will also
> > +become active. The active channel is propagated to other CTIs via the CTM,
> > +activating connected output triggers there, unless filtered by the CTI
> > +channel gate.
> > +
> > +It is also possible to activate a channel using system software directly
> > +programming registers in the CTI.
> > +
> > +The CTIs are registered by the system to be associated with CPUs and/or other
> > +CoreSight devices on the trace data path. When these devices are enabled the
> > +attached CTIs will also be enabled. By default/on power up the CTIs have
> > +no programmed trigger/channel attachments, so will not affect the system
> > +until explicitly programmed.
> > +
> > +The hardware trigger connections between CTIs and devices is implementation
> > +defined, unless the CPU/ETM combination is a v8 architecture, in which case
> > +the connections have an architecturally defined standard layout.
> > +
> > +The hardware trigger signals can also be connected to non-CoreSight devices
> > +(e.g. UART), or be propagated off chip as hardware IO lines.
> > +
> > +All the CTI devices are associated with a CTM. On many systems there will be a
> > +single effective CTM (one CTM, or multiple CTMs all interconnected), but it is
> > +possible that systems can have nets of CTIs+CTM that are not interconnected by
> > +a CTM to each other. On these systems a CTM index is declared to associate
> > +CTI devices that are interconnected via a given CTM.
> > +
> > +Sysfs files and directories
> > +---------------------------
> > +
> > +The CTI devices appear on the existing CoreSight bus alongside the other
> > +CoreSight devices::
> > +
> > +    >$ ls /sys/bus/coresight/devices
> > +     cti_cpu0  cti_cpu2  cti_sys0  etm0  etm2  funnel0  replicator0  tmc_etr0
> > +     cti_cpu1  cti_cpu3  cti_sys1  etm1  etm3  funnel1  tmc_etf0     tpiu0
> > +
> > +The ``cti_cpu<N>`` named CTIs are associated with a CPU, and any ETM used by
> > +that core. the ``cti_sys<N>`` CTIs are general system infrastructure CTIs that
>
>               The
>
> > +can be associated with other CoreSight devices, or other system hardware
> > +capable of generating or using trigger signals.::
> > +
> > +  >$ ls /sys/bus/coresight/devices/etm0/cti_cpu0
> > +  channels  ctmid  enable  nr_trigger_cons mgmt  power  regs  subsystem
> > +  triggers0 triggers1  uevent
> > +
> > +*Key file items are:-*
> > +   * ``enable``: enables/disables the CTI.
> > +   * ``ctmid`` : associated CTM - only relevant if system has multiple CTI+CTM
> > +     clusters that are not interconnected.
> > +   * ``nr_trigger_cons`` : total connections - triggers<N> directories.
> > +
> > +*Sub-directories:-*
> > +   * ``triggers<N>``: contains list of triggers for an individual connection.
> > +   * ``channels``: Contains the channel API - CTI main programming interface.
> > +   * ``regs``: Gives access to the raw programmable CTI regs.
> > +   * ``mgmt``: the standard CoreSight management registers.
> > +
> > +
> > +triggers<N> directories
> > +~~~~~~~~~~~~~~~~~~~~~~~
> > +
> > +Individual trigger connection information. This describes trigger signals for
> > +CoreSight and non-CoreSight connections.
> > +
> > +Each triggers directory has a set of parameters describing the triggers for
> > +the connection.
> > +
> > +   * ``name`` : name of connection
> > +   * ``in_signals`` : input trigger signal indexes used in this connection.
> > +   * ``in_types`` : functional types for in signals.
> > +   * ``out_signals`` : output trigger signals for this connection.
> > +   * ``out_types`` : functional types for out signals.
> > +
> > +e.g::
> > +
> > +    >$ ls ./cti_cpu0/triggers0/
> > +    in_signals  in_types  name  out_signals  out_types
> > +    >$ cat ./cti_cpu0/triggers0/name
> > +    cpu0
> > +    >$ cat ./cti_cpu0/triggers0/out_signals
> > +    0-2
> > +    >$ cat ./cti_cpu0/triggers0/out_types
> > +    pe_edbgreq pe_dbgrestart pe_ctiirq
> > +    >$ cat ./cti_cpu0/triggers0/in_signals
> > +    0-1
> > +    >$ cat ./cti_cpu0/triggers0/in_types
> > +    pe_dbgtrigger pe_pmuirq
> > +
> > +If a connection has zero signals in either the 'in' or 'out' triggers then
> > +those parameters will be omitted.
> > +
> > +Channels API Directory
> > +~~~~~~~~~~~~~~~~~~~~~~
> > +
> > +This provides an easy way to attach triggers to channels, without needing
> > +the multiple register operations that are required if manipulating the
> > +'regs' sub-dir elements directly.
>
> spell out: sub-directory
>
> > +
> > +A number of files provide this API::
> > +
> > +   >$ ls ./cti_sys0/channels/
> > +   chan_clear         chan_inuse         chan_xtrigs_view      trigin_detach
> > +   chan_free          chan_pulse         chan_xtrigs_view_sel  trigout_attach
> > +   chan_gate_disable  chan_set           trig_filter_enable    trigout_detach
> > +   chan_gate_enable   chan_xtrigs_reset  trigin_attach         trigout_filtered
> > +
> > +Most access to these elements take the form::
> > +
> > +  echo <chan> [<trigger>] > /<device_path>/<operation>
> > +
> > +where the optional <trigger> is only needed for trigXX_attach | detach
> > +operations.
> > +
> > +e.g.::
> > +
> > +   >$ echo 0 1 > ./cti_sys0/channels/trigout_attach
> > +   >$ echo 0 > ./cti_sys0/channels/chan_set
> > +
> > +Attaches trigout(1) to channel(0), then activates channel(0) generating a
> > +set state on cti_sys0.trigout(1)
> > +
> > +
> > +*API operations*
> > +
> > +   * ``trigin_attach, trigout_attach``: Attach a channel to a trigger signal.
> > +   * ``trigin_detach, trigout_detach``: Detach a channel from a trigger signal.
> > +   * ``chan_set``: Set the channel - the set state will be propagated around
> > +     the CTM to other connected devices.
> > +   * ``chan_clear``: Clear the channel.
> > +   * ``chan_pulse``: Set the channel for a single CoreSight clock cycle.
> > +   * ``chan_gate_enable``: Write operation sets the CTI gate to propagate
> > +     (enable) the channel to other devices. This operation takes a channel
> > +     number. CTI gate is enabled for all channels by default at power up. Read
> > +     to list the currently enabled channels on the gate.
> > +   * ``chan_gate_disable``: Write channel number to disable gate for that
> > +     channel.
> > +   * ``chan_inuse``: Show the current channels attached to any signal
> > +   * ``chan_free``: Show channels with no attached signals.
> > +   * ``chan_xtrig_view``: write a channel number to select a channel to view,
> > +     read to show the cross triggers programmed for the selected channel.
> > +   * ``trig_filter_enable``: Defaults to enabled, disable to allow potentially
> > +     dangerous output signals to be set.
> > +   * ``trigout_filtered``: Trigger out signals that are prevented from being
> > +     set if filtering ``trig_filter_enable`` is enabled. One use is to prevent
> > +     accidental ``EDBGREQ`` signals stopping a core.
> > +   * ``chan_xtrigs_reset``: Write 1 to clear all channel / trigger programming.
> > +     Resets device hardware to default state.
> > +
> > +
> > +The example below attaches input trigger index 1 to channel 2, and output
> > +trigger index 6 to the same channel. It then examines the state of the
> > +channel / trigger connections using the appropriate sysfs attributes.
> > +
> > +The settings mean that if either input trigger 1, or channel 2 go active then
> > +trigger out 6 will go active. We then enable the CTI, and use the software
> > +channel control to activate channel 2. We see the active channel on the
> > +``choutstatus`` register and the active signal on the ``trigoutstatus``
> > +register. Finally clearing the channel removes this.
> > +
> > +e.g.::
> > +
> > +   .../cti_sys0/channels# echo 2 1 > trigin_attach
> > +   .../cti_sys0/channels# echo 2 6 > trigout_attach
> > +   .../cti_sys0/channels# cat chan_free
> > +   0-1,3
> > +   .../cti_sys0/channels# cat chan_inuse
> > +   2
> > +   .../cti_sys0/channels# echo 2 > chan_xtrigs_view
> > +   .../cti_sys0/channels# cat chan_xtrigs_view
> > +   [2] IN: 1 OUT: 6
> > +   .../cti_sys0/# echo 1 > enable
> > +   .../cti_sys0/channels# echo 2 > chan_set
> > +   .../cti_sys0/channels# cat ../regs/choutstatus
> > +   0x4
> > +   .../cti_sys0/channels# cat ../regs/trigoutstatus
> > +   0x40
> > +   .../cti_sys0/channels# echo 2 > chan_clear
> > +   .../cti_sys0/channels# cat ../regs/trigoutstatus
> > +   0x0
> > +   .../cti_sys0/channels# cat ../regs/choutstatus
> > +   0x0
>
>
> Reviewed-by: Randy Dunlap <rdunlap@infradead.org>
>
> thanks.
> --
> ~Randy
>
diff mbox series

Patch

diff --git a/Documentation/trace/coresight/coresight-ect.rst b/Documentation/trace/coresight/coresight-ect.rst
new file mode 100644
index 000000000000..3e06588f24fa
--- /dev/null
+++ b/Documentation/trace/coresight/coresight-ect.rst
@@ -0,0 +1,211 @@ 
+=============================================
+CoreSight Embedded Cross Trigger (CTI & CTM).
+=============================================
+
+    :Author:   Mike Leach <mike.leach@linaro.org>
+    :Date:     November 2019
+
+Hardware Description
+--------------------
+
+The CoreSight Cross Trigger Interface (CTI) is a hardware device that takes
+individual input and output hardware signals known as triggers to and from
+devices and interconnects them via the Cross Trigger Matrix (CTM) to other
+devices via numbered channels, in order to propagate events between devices.
+
+e.g.::
+
+ 0000000  in_trigs  :::::::
+ 0 C   0----------->:     :             +======>(other CTI channel IO)
+ 0  P  0<-----------:     :             v
+ 0   U 0  out_trigs :     : Channels  *****      :::::::
+ 0000000            : CTI :<=========>*CTM*<====>: CTI :---+
+ #######  in_trigs  :     : (id 0-3)  *****      :::::::   v
+ # ETM #----------->:     :                         ^   #######
+ #     #<-----------:     :                         +---# ETR #
+ ####### out_trigs  :::::::                             #######
+
+The CTI driver enables the programming of the CTI to attach triggers to
+channels. When an input trigger becomes active, the attached channel will
+become active. Any output trigger attached to that channel will also
+become active. The active channel is propagated to other CTIs via the CTM,
+activating connected output triggers there, unless filtered by the CTI
+channel gate.
+
+It is also possible to activate a channel using system software directly
+programming registers in the CTI.
+
+The CTIs are registered by the system to be associated with CPUs and/or other
+CoreSight devices on the trace data path. When these devices are enabled the
+attached CTIs will also be enabled. By default/on power up the CTIs have
+no programmed trigger/channel attachments, so will not affect the system
+until explicitly programmed.
+
+The hardware trigger connections between CTIs and devices is implementation
+defined, unless the CPU/ETM combination is a v8 architecture, in which case
+the connections have an architecturally defined standard layout.
+
+The hardware trigger signals can also be connected to non-CoreSight devices
+(e.g. UART), or be propagated off chip as hardware IO lines.
+
+All the CTI devices are associated with a CTM. On many systems there will be a
+single effective CTM (one CTM, or multiple CTMs all interconnected), but it is
+possible that systems can have nets of CTIs+CTM that are not interconnected by
+a CTM to each other. On these systems a CTM index is declared to associate
+CTI devices that are interconnected via a given CTM.
+
+Sysfs files and directories
+---------------------------
+
+The CTI devices appear on the existing CoreSight bus alongside the other
+CoreSight devices::
+
+    >$ ls /sys/bus/coresight/devices
+     cti_cpu0  cti_cpu2  cti_sys0  etm0  etm2  funnel0  replicator0  tmc_etr0
+     cti_cpu1  cti_cpu3  cti_sys1  etm1  etm3  funnel1  tmc_etf0     tpiu0
+
+The ``cti_cpu<N>`` named CTIs are associated with a CPU, and any ETM used by
+that core. the ``cti_sys<N>`` CTIs are general system infrastructure CTIs that
+can be associated with other CoreSight devices, or other system hardware
+capable of generating or using trigger signals.::
+
+  >$ ls /sys/bus/coresight/devices/etm0/cti_cpu0
+  channels  ctmid  enable  nr_trigger_cons mgmt  power  regs  subsystem
+  triggers0 triggers1  uevent
+
+*Key file items are:-*
+   * ``enable``: enables/disables the CTI.
+   * ``ctmid`` : associated CTM - only relevant if system has multiple CTI+CTM
+     clusters that are not interconnected.
+   * ``nr_trigger_cons`` : total connections - triggers<N> directories.
+
+*Sub-directories:-*
+   * ``triggers<N>``: contains list of triggers for an individual connection.
+   * ``channels``: Contains the channel API - CTI main programming interface.
+   * ``regs``: Gives access to the raw programmable CTI regs.
+   * ``mgmt``: the standard CoreSight management registers.
+
+
+triggers<N> directories
+~~~~~~~~~~~~~~~~~~~~~~~
+
+Individual trigger connection information. This describes trigger signals for
+CoreSight and non-CoreSight connections.
+
+Each triggers directory has a set of parameters describing the triggers for
+the connection.
+
+   * ``name`` : name of connection
+   * ``in_signals`` : input trigger signal indexes used in this connection.
+   * ``in_types`` : functional types for in signals.
+   * ``out_signals`` : output trigger signals for this connection.
+   * ``out_types`` : functional types for out signals.
+
+e.g::
+
+    >$ ls ./cti_cpu0/triggers0/
+    in_signals  in_types  name  out_signals  out_types
+    >$ cat ./cti_cpu0/triggers0/name
+    cpu0
+    >$ cat ./cti_cpu0/triggers0/out_signals
+    0-2
+    >$ cat ./cti_cpu0/triggers0/out_types
+    pe_edbgreq pe_dbgrestart pe_ctiirq
+    >$ cat ./cti_cpu0/triggers0/in_signals
+    0-1
+    >$ cat ./cti_cpu0/triggers0/in_types
+    pe_dbgtrigger pe_pmuirq
+
+If a connection has zero signals in either the 'in' or 'out' triggers then
+those parameters will be omitted.
+
+Channels API Directory
+~~~~~~~~~~~~~~~~~~~~~~
+
+This provides an easy way to attach triggers to channels, without needing
+the multiple register operations that are required if manipulating the
+'regs' sub-dir elements directly.
+
+A number of files provide this API::
+
+   >$ ls ./cti_sys0/channels/
+   chan_clear         chan_inuse         chan_xtrigs_view      trigin_detach
+   chan_free          chan_pulse         chan_xtrigs_view_sel  trigout_attach
+   chan_gate_disable  chan_set           trig_filter_enable    trigout_detach
+   chan_gate_enable   chan_xtrigs_reset  trigin_attach         trigout_filtered
+
+Most access to these elements take the form::
+
+  echo <chan> [<trigger>] > /<device_path>/<operation>
+
+where the optional <trigger> is only needed for trigXX_attach | detach
+operations.
+
+e.g.::
+
+   >$ echo 0 1 > ./cti_sys0/channels/trigout_attach
+   >$ echo 0 > ./cti_sys0/channels/chan_set
+
+Attaches trigout(1) to channel(0), then activates channel(0) generating a
+set state on cti_sys0.trigout(1)
+
+
+*API operations*
+
+   * ``trigin_attach, trigout_attach``: Attach a channel to a trigger signal.
+   * ``trigin_detach, trigout_detach``: Detach a channel from a trigger signal.
+   * ``chan_set``: Set the channel - the set state will be propagated around
+     the CTM to other connected devices.
+   * ``chan_clear``: Clear the channel.
+   * ``chan_pulse``: Set the channel for a single CoreSight clock cycle.
+   * ``chan_gate_enable``: Write operation sets the CTI gate to propagate
+     (enable) the channel to other devices. This operation takes a channel
+     number. CTI gate is enabled for all channels by default at power up. Read
+     to list the currently enabled channels on the gate.
+   * ``chan_gate_disable``: Write channel number to disable gate for that
+     channel.
+   * ``chan_inuse``: Show the current channels attached to any signal
+   * ``chan_free``: Show channels with no attached signals.
+   * ``chan_xtrig_view``: write a channel number to select a channel to view,
+     read to show the cross triggers programmed for the selected channel.
+   * ``trig_filter_enable``: Defaults to enabled, disable to allow potentially
+     dangerous output signals to be set.
+   * ``trigout_filtered``: Trigger out signals that are prevented from being
+     set if filtering ``trig_filter_enable`` is enabled. One use is to prevent
+     accidental ``EDBGREQ`` signals stopping a core.
+   * ``chan_xtrigs_reset``: Write 1 to clear all channel / trigger programming.
+     Resets device hardware to default state.
+
+
+The example below attaches input trigger index 1 to channel 2, and output
+trigger index 6 to the same channel. It then examines the state of the
+channel / trigger connections using the appropriate sysfs attributes.
+
+The settings mean that if either input trigger 1, or channel 2 go active then
+trigger out 6 will go active. We then enable the CTI, and use the software
+channel control to activate channel 2. We see the active channel on the
+``choutstatus`` register and the active signal on the ``trigoutstatus``
+register. Finally clearing the channel removes this.
+
+e.g.::
+
+   .../cti_sys0/channels# echo 2 1 > trigin_attach
+   .../cti_sys0/channels# echo 2 6 > trigout_attach
+   .../cti_sys0/channels# cat chan_free
+   0-1,3
+   .../cti_sys0/channels# cat chan_inuse
+   2
+   .../cti_sys0/channels# echo 2 > chan_xtrigs_view
+   .../cti_sys0/channels# cat chan_xtrigs_view
+   [2] IN: 1 OUT: 6
+   .../cti_sys0/# echo 1 > enable
+   .../cti_sys0/channels# echo 2 > chan_set
+   .../cti_sys0/channels# cat ../regs/choutstatus
+   0x4
+   .../cti_sys0/channels# cat ../regs/trigoutstatus
+   0x40
+   .../cti_sys0/channels# echo 2 > chan_clear
+   .../cti_sys0/channels# cat ../regs/trigoutstatus
+   0x0
+   .../cti_sys0/channels# cat ../regs/choutstatus
+   0x0
diff --git a/Documentation/trace/coresight/coresight.rst b/Documentation/trace/coresight/coresight.rst
index a566719f8e7e..108600ee1e12 100644
--- a/Documentation/trace/coresight/coresight.rst
+++ b/Documentation/trace/coresight/coresight.rst
@@ -491,8 +491,21 @@  interface provided for that purpose by the generic STM API::
 
 Details on how to use the generic STM API can be found here:- :doc:`../stm` [#second]_.
 
+The CTI & CTM Modules
+---------------------
+
+The CTI (Cross Trigger Interface) provides a set of trigger signals between
+individual CTIs and components, and can propagate these between all CTIs via
+channels on the CTM (Cross Trigger Matrix).
+
+A separate documentation file is provided to explain the use of these devices.
+(:doc:`coresight-ect`) [#fourth]_.
+
+
 .. [#first] Documentation/ABI/testing/sysfs-bus-coresight-devices-stm
 
 .. [#second] Documentation/trace/stm.rst
 
 .. [#third] https://github.com/Linaro/perf-opencsd
+
+.. [#fourth] Documentation/trace/coresight/coresight-ect.rst