@@ -69,8 +69,12 @@ static const struct tsens_ops ops_generic_v2 = {
.get_temp = get_temp_tsens_v2,
};
+const struct tsens_data data_tsens_v2 = {
+ .ops = &ops_generic_v2,
+};
+
+/* Kept around for backward compatibility with old msm8996.dtsi */
const struct tsens_data data_8996 = {
.num_sensors = 13,
.ops = &ops_generic_v2,
};
-
@@ -72,6 +72,9 @@ static const struct of_device_id tsens_table[] = {
}, {
.compatible = "qcom,msm8996-tsens",
.data = &data_8996,
+ }, {
+ .compatible = "qcom,tsens-v2",
+ .data = &data_tsens_v2,
},
{}
};
@@ -88,6 +88,9 @@ void compute_intercept_slope(struct tsens_device *, u32 *, u32 *, u32);
int init_common(struct tsens_device *);
int get_temp_common(struct tsens_device *, int, int *);
-extern const struct tsens_data data_8916, data_8974, data_8960, data_8996;
+/* TSENS v1 targets */
+extern const struct tsens_data data_8916, data_8974, data_8960;
+/* TSENS v2 targets */
+extern const struct tsens_data data_8996, data_tsens_v2;
#endif /* __QCOM_TSENS_H__ */
SDM845 uses v2 of the TSENS IP block but the get_temp() function appears to be identical across v2.x.y in code seen so far. We use the generic get_temp() function defined as part of ops_generic_v2. Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org> --- drivers/thermal/qcom/tsens-v2.c | 6 +++++- drivers/thermal/qcom/tsens.c | 3 +++ drivers/thermal/qcom/tsens.h | 5 ++++- 3 files changed, 12 insertions(+), 2 deletions(-) -- 2.7.4