diff mbox series

[3/4] power: supply: sc27xx: Fix the incorrect formula when converting capacity to coulomb counter

Message ID 7d23781552d6ff1fe6bbabfc56cbbb04d807fffa.1547544142.git.baolin.wang@linaro.org
State Accepted
Commit 3a28f203c57944ac98a3adcbfacdbfa385966972
Headers show
Series None | expand

Commit Message

(Exiting) Baolin Wang Jan. 15, 2019, 10:32 a.m. UTC
We should multiply the calibrated current data (cur_1000ma_adc) when
converting current capacity (mAh) to coulomb counter, which can get
an accurate coulomb counter from the fuel gauge controller.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>

---
 drivers/power/supply/sc27xx_fuel_gauge.c |    2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

-- 
1.7.9.5
diff mbox series

Patch

diff --git a/drivers/power/supply/sc27xx_fuel_gauge.c b/drivers/power/supply/sc27xx_fuel_gauge.c
index 4926b8a..ea1349f 100644
--- a/drivers/power/supply/sc27xx_fuel_gauge.c
+++ b/drivers/power/supply/sc27xx_fuel_gauge.c
@@ -731,7 +731,7 @@  static int sc27xx_fgu_cap_to_clbcnt(struct sc27xx_fgu_data *data, int capacity)
 	 * Convert current capacity (mAh) to coulomb counter according to the
 	 * formula: 1 mAh =3.6 coulomb.
 	 */
-	return DIV_ROUND_CLOSEST(cur_cap * 36, 10);
+	return DIV_ROUND_CLOSEST(cur_cap * 36 * data->cur_1000ma_adc, 10);
 }
 
 static int sc27xx_fgu_calibration(struct sc27xx_fgu_data *data)