On 26/07/2019 00:18, Amit Kucheria wrote: > msm8916 uses sensors 0, 1, 2, 4 and 5. Sensor 3 is NOT used. Fixup the > device tree so that the correct sensor ID is used and as a result we can > actually check the temperature for the cpu2_3 sensor. > > Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org> This change matches the documentation available in the Qcom website. Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org> > --- > arch/arm64/boot/dts/qcom/msm8916.dtsi | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi > index 5ea9fb8f2f87..8686e101905c 100644 > --- a/arch/arm64/boot/dts/qcom/msm8916.dtsi > +++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi > @@ -179,7 +179,7 @@ > polling-delay-passive = <250>; > polling-delay = <1000>; > > - thermal-sensors = <&tsens 4>; > + thermal-sensors = <&tsens 5>; > > trips { > cpu0_1_alert0: trip-point@0 { > @@ -209,7 +209,7 @@ > polling-delay-passive = <250>; > polling-delay = <1000>; > > - thermal-sensors = <&tsens 3>; > + thermal-sensors = <&tsens 4>; > > trips { > cpu2_3_alert0: trip-point@0 { > -- <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook | <http://twitter.com/#!/linaroorg> Twitter | <http://www.linaro.org/linaro-blog/> Blog
diff --git a/arch/arm64/boot/dts/qcom/msm8916.dtsi b/arch/arm64/boot/dts/qcom/msm8916.dtsi index 5ea9fb8f2f87..8686e101905c 100644 --- a/arch/arm64/boot/dts/qcom/msm8916.dtsi +++ b/arch/arm64/boot/dts/qcom/msm8916.dtsi @@ -179,7 +179,7 @@ polling-delay-passive = <250>; polling-delay = <1000>; - thermal-sensors = <&tsens 4>; + thermal-sensors = <&tsens 5>; trips { cpu0_1_alert0: trip-point@0 { @@ -209,7 +209,7 @@ polling-delay-passive = <250>; polling-delay = <1000>; - thermal-sensors = <&tsens 3>; + thermal-sensors = <&tsens 4>; trips { cpu2_3_alert0: trip-point@0 {
msm8916 uses sensors 0, 1, 2, 4 and 5. Sensor 3 is NOT used. Fixup the device tree so that the correct sensor ID is used and as a result we can actually check the temperature for the cpu2_3 sensor. Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org> --- arch/arm64/boot/dts/qcom/msm8916.dtsi | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) -- 2.17.1