diff mbox series

[5.7,153/477] thermal/drivers/ti-soc-thermal: Avoid dereferencing ERR_PTR

Message ID 20200623195414.829037889@linuxfoundation.org
State Superseded
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman June 23, 2020, 7:52 p.m. UTC
From: Sudip Mukherjee <sudipm.mukherjee@gmail.com>

[ Upstream commit 7440f518dad9d861d76c64956641eeddd3586f75 ]

On error the function ti_bandgap_get_sensor_data() returns the error
code in ERR_PTR() but we only checked if the return value is NULL or
not. And, so we can dereference an error code inside ERR_PTR.
While at it, convert a check to IS_ERR_OR_NULL.

Signed-off-by: Sudip Mukherjee <sudipm.mukherjee@gmail.com>
Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200424161944.6044-1-sudipm.mukherjee@gmail.com
Signed-off-by: Sasha Levin <sashal@kernel.org>
---
 drivers/thermal/ti-soc-thermal/ti-thermal-common.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index d3e959d01606c..85776db4bf346 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -169,7 +169,7 @@  int ti_thermal_expose_sensor(struct ti_bandgap *bgp, int id,
 
 	data = ti_bandgap_get_sensor_data(bgp, id);
 
-	if (!data || IS_ERR(data))
+	if (!IS_ERR_OR_NULL(data))
 		data = ti_thermal_build_data(bgp, id);
 
 	if (!data)
@@ -196,7 +196,7 @@  int ti_thermal_remove_sensor(struct ti_bandgap *bgp, int id)
 
 	data = ti_bandgap_get_sensor_data(bgp, id);
 
-	if (data && data->ti_thermal) {
+	if (!IS_ERR_OR_NULL(data) && data->ti_thermal) {
 		if (data->our_zone)
 			thermal_zone_device_unregister(data->ti_thermal);
 	}
@@ -262,7 +262,7 @@  int ti_thermal_unregister_cpu_cooling(struct ti_bandgap *bgp, int id)
 
 	data = ti_bandgap_get_sensor_data(bgp, id);
 
-	if (data) {
+	if (!IS_ERR_OR_NULL(data)) {
 		cpufreq_cooling_unregister(data->cool_dev);
 		if (data->policy)
 			cpufreq_cpu_put(data->policy);