diff mbox series

[06/10] dt-bindings:iio:afe:current-sense-shunt: txt to yaml conversion.

Message ID 20201031181242.742301-7-jic23@kernel.org
State New
Headers show
Series dt-bindings: iio: conversion of consumer drivers | expand

Commit Message

Jonathan Cameron Oct. 31, 2020, 6:12 p.m. UTC
From: Jonathan Cameron <Jonathan.Cameron@huawei.com>

Very simple binding. As such straight forward conversion.

Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Cc: Peter Rosin <peda@axentia.se>
---
 .../bindings/iio/afe/current-sense-shunt.txt  | 41 ------------
 .../bindings/iio/afe/current-sense-shunt.yaml | 65 +++++++++++++++++++
 2 files changed, 65 insertions(+), 41 deletions(-)
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.txt b/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.txt
deleted file mode 100644
index 0f67108a07b6..000000000000
--- a/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.txt
+++ /dev/null
@@ -1,41 +0,0 @@ 
-Current Sense Shunt
-===================
-
-When an io-channel measures the voltage over a current sense shunt,
-the interesting measurement is almost always the current through the
-shunt, not the voltage over it. This binding describes such a current
-sense circuit.
-
-Required properties:
-- compatible : "current-sense-shunt"
-- io-channels : Channel node of a voltage io-channel.
-- shunt-resistor-micro-ohms : The shunt resistance in microohms.
-
-Example:
-The system current is measured by measuring the voltage over a
-3.3 ohms shunt resistor.
-
-sysi {
-	compatible = "current-sense-shunt";
-	io-channels = <&tiadc 0>;
-
-	/* Divide the voltage by 3300000/1000000 (or 3.3) for the current. */
-	shunt-resistor-micro-ohms = <3300000>;
-};
-
-&i2c {
-	tiadc: adc@48 {
-		compatible = "ti,ads1015";
-		reg = <0x48>;
-		#io-channel-cells = <1>;
-
-		#address-cells = <1>;
-		#size-cells = <0>;
-
-		channel@0 { /* IN0,IN1 differential */
-			reg = <0>;
-			ti,gain = <1>;
-			ti,datarate = <4>;
-		};
-	};
-};
diff --git a/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.yaml b/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.yaml
new file mode 100644
index 000000000000..2f18409c64e3
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/afe/current-sense-shunt.yaml
@@ -0,0 +1,65 @@ 
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/afe/current-sense-shunt.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Current Sense Shunt
+
+maintainers:
+  - Peter Rosin <peda@axentia.se>
+
+description: |
+  When an io-channel measures the voltage over a current sense shunt,
+  the interesting measurement is almost always the current through the
+  shunt, not the voltage over it. This binding describes such a current
+  sense circuit.
+
+properties:
+  compatible:
+    const: current-sense-shunt
+
+  io-channels:
+    maxItems: 1
+    description: |
+      Channel node of a voltage io-channel.
+
+  shunt-resistor-micro-ohms:
+    $ref: /schemas/types.yaml#/definitions/uint32
+    description: The shunt resistance.
+
+required:
+  - compatible
+  - io-channels
+  - shunt-resistor-micro-ohms
+
+additionalProperties: false
+
+examples:
+  - |
+    i2c {
+        #address-cells = <1>;
+        #size-cells = <0>;
+        tiadc: adc@48 {
+            compatible = "ti,ads1015";
+            reg = <0x48>;
+            #io-channel-cells = <1>;
+
+            #address-cells = <1>;
+            #size-cells = <0>;
+
+            channel@0 { /* IN0,IN1 differential */
+                reg = <0>;
+                ti,gain = <1>;
+                ti,datarate = <4>;
+            };
+        };
+    };
+    sysi {
+        compatible = "current-sense-shunt";
+        io-channels = <&tiadc 0>;
+
+        /* Divide the voltage by 3300000/1000000 (or 3.3) for the current. */
+        shunt-resistor-micro-ohms = <3300000>;
+    };
+...