diff mbox series

[v2,07/29] dt-bindings:iio:pressure:meas,ms5611 yaml conversion.

Message ID 20201031134110.724233-8-jic23@kernel.org
State New
Headers show
Series dt-bindings:iio: Another set of yaml conversions. | expand

Commit Message

Jonathan Cameron Oct. 31, 2020, 1:40 p.m. UTC
From: Jonathan Cameron <Jonathan.Cameron@huawei.com>


One addition here was to put in a 20MHz maximum for the SPI bus
as specified in the datasheets of both support parts.

Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>

Reviewed-by: Rob Herring <robh@kernel.org>

Cc: Tomasz Duszynski <tduszyns@gmail.com>
---
 .../bindings/iio/pressure/meas,ms5611.yaml    | 57 +++++++++++++++++++
 .../bindings/iio/pressure/ms5611.txt          | 19 -------
 2 files changed, 57 insertions(+), 19 deletions(-)

-- 
2.28.0
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/iio/pressure/meas,ms5611.yaml b/Documentation/devicetree/bindings/iio/pressure/meas,ms5611.yaml
new file mode 100644
index 000000000000..4f06707450bf
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/pressure/meas,ms5611.yaml
@@ -0,0 +1,57 @@ 
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/pressure/meas,ms5611.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Measurement Specialities ms5611 and similar pressure sensors
+
+maintainers:
+  - Tomasz Duszynski <tduszyns@gmail.com>
+
+description: |
+  Pressure sensors from MEAS Switzerland with SPI and I2C bus interfaces.
+
+properties:
+  compatible:
+    enum:
+      - meas,ms5607
+      - meas,ms5611
+
+  reg:
+    maxItems: 1
+
+  vdd-supply: true
+
+  spi-max-frequency:
+    maximum: 20000000
+
+required:
+  - compatible
+  - reg
+
+additionalProperties: false
+
+examples:
+  - |
+    i2c {
+        #address-cells = <1>;
+        #size-cells = <0>;
+
+        pressure@77 {
+            compatible = "meas,ms5607";
+            reg = <0x77>;
+            vdd-supply = <&ldo_3v3_gnss>;
+        };
+    };
+  - |
+    spi {
+        #address-cells = <1>;
+        #size-cells = <0>;
+        pressure@0 {
+            compatible = "meas,ms5611";
+            reg = <0>;
+            vdd-supply = <&ldo_3v3_gnss>;
+        };
+    };
+...
diff --git a/Documentation/devicetree/bindings/iio/pressure/ms5611.txt b/Documentation/devicetree/bindings/iio/pressure/ms5611.txt
deleted file mode 100644
index 17bca866c084..000000000000
--- a/Documentation/devicetree/bindings/iio/pressure/ms5611.txt
+++ /dev/null
@@ -1,19 +0,0 @@ 
-MEAS ms5611 family pressure sensors
-
-Pressure sensors from MEAS Switzerland with SPI and I2C bus interfaces.
-
-Required properties:
-- compatible: "meas,ms5611" or "meas,ms5607"
-- reg: the I2C address or SPI chip select the device will respond to
-
-Optional properties:
-- vdd-supply: an optional regulator that needs to be on to provide VDD
-  power to the sensor.
-
-Example:
-
-ms5607@77 {
-	compatible = "meas,ms5607";
-	reg = <0x77>;
-	vdd-supply = <&ldo_3v3_gnss>;
-};