diff mbox series

[net-next,v2,1/1] net: phy: nxp-tja11xx: log critical health state

Message ID 20210811063712.19695-1-o.rempel@pengutronix.de
State New
Headers show
Series [net-next,v2,1/1] net: phy: nxp-tja11xx: log critical health state | expand

Commit Message

Oleksij Rempel Aug. 11, 2021, 6:37 a.m. UTC
TJA1102 provides interrupt notification for the critical health states
like overtemperature and undervoltage.

The overtemperature bit is set if package temperature is beyond 155C°.
This functionality was tested by heating the package up to 200C°

The undervoltage bit is set if supply voltage drops beyond some critical
threshold. Currently not tested.

In a typical use case, both of this events should be logged and stored
(or send to some remote system) for further investigations.

Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
---
 drivers/net/phy/nxp-tja11xx.c | 13 +++++++++++--
 1 file changed, 11 insertions(+), 2 deletions(-)

Comments

Andrew Lunn Aug. 11, 2021, 2:59 p.m. UTC | #1
On Wed, Aug 11, 2021 at 08:37:12AM +0200, Oleksij Rempel wrote:
> TJA1102 provides interrupt notification for the critical health states
> like overtemperature and undervoltage.
> 
> The overtemperature bit is set if package temperature is beyond 155C°.
> This functionality was tested by heating the package up to 200C°
> 
> The undervoltage bit is set if supply voltage drops beyond some critical
> threshold. Currently not tested.
> 
> In a typical use case, both of this events should be logged and stored
> (or send to some remote system) for further investigations.
> 
> Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>

Reviewed-by: Andrew Lunn <andrew@lunn.ch>

    Andrew
patchwork-bot+netdevbpf@kernel.org Aug. 12, 2021, 10 a.m. UTC | #2
Hello:

This patch was applied to netdev/net-next.git (refs/heads/master):

On Wed, 11 Aug 2021 08:37:12 +0200 you wrote:
> TJA1102 provides interrupt notification for the critical health states

> like overtemperature and undervoltage.

> 

> The overtemperature bit is set if package temperature is beyond 155C°.

> This functionality was tested by heating the package up to 200C°

> 

> The undervoltage bit is set if supply voltage drops beyond some critical

> threshold. Currently not tested.

> 

> [...]


Here is the summary with links:
  - [net-next,v2,1/1] net: phy: nxp-tja11xx: log critical health state
    https://git.kernel.org/netdev/net-next/c/e0ba60509d64

You are awesome, thank you!
--
Deet-doot-dot, I am a bot.
https://korg.docs.kernel.org/patchwork/pwbot.html
diff mbox series

Patch

diff --git a/drivers/net/phy/nxp-tja11xx.c b/drivers/net/phy/nxp-tja11xx.c
index afd7afa1f498..9944cc501806 100644
--- a/drivers/net/phy/nxp-tja11xx.c
+++ b/drivers/net/phy/nxp-tja11xx.c
@@ -47,12 +47,14 @@ 
 #define MII_INTSRC_LINK_FAIL		BIT(10)
 #define MII_INTSRC_LINK_UP		BIT(9)
 #define MII_INTSRC_MASK			(MII_INTSRC_LINK_FAIL | MII_INTSRC_LINK_UP)
-#define MII_INTSRC_TEMP_ERR		BIT(1)
 #define MII_INTSRC_UV_ERR		BIT(3)
+#define MII_INTSRC_TEMP_ERR		BIT(1)
 
 #define MII_INTEN			22
 #define MII_INTEN_LINK_FAIL		BIT(10)
 #define MII_INTEN_LINK_UP		BIT(9)
+#define MII_INTEN_UV_ERR		BIT(3)
+#define MII_INTEN_TEMP_ERR		BIT(1)
 
 #define MII_COMMSTAT			23
 #define MII_COMMSTAT_LINK_UP		BIT(15)
@@ -607,7 +609,8 @@  static int tja11xx_config_intr(struct phy_device *phydev)
 		if (err)
 			return err;
 
-		value = MII_INTEN_LINK_FAIL | MII_INTEN_LINK_UP;
+		value = MII_INTEN_LINK_FAIL | MII_INTEN_LINK_UP |
+			MII_INTEN_UV_ERR | MII_INTEN_TEMP_ERR;
 		err = phy_write(phydev, MII_INTEN, value);
 	} else {
 		err = phy_write(phydev, MII_INTEN, value);
@@ -622,6 +625,7 @@  static int tja11xx_config_intr(struct phy_device *phydev)
 
 static irqreturn_t tja11xx_handle_interrupt(struct phy_device *phydev)
 {
+	struct device *dev = &phydev->mdio.dev;
 	int irq_status;
 
 	irq_status = phy_read(phydev, MII_INTSRC);
@@ -630,6 +634,11 @@  static irqreturn_t tja11xx_handle_interrupt(struct phy_device *phydev)
 		return IRQ_NONE;
 	}
 
+	if (irq_status & MII_INTSRC_TEMP_ERR)
+		dev_warn(dev, "Overtemperature error detected (temp > 155C°).\n");
+	if (irq_status & MII_INTSRC_UV_ERR)
+		dev_warn(dev, "Undervoltage error detected.\n");
+
 	if (!(irq_status & MII_INTSRC_MASK))
 		return IRQ_NONE;