Implement a method to change watchdog timeout configuration based on DT
binding ("dlg,wdt-sd"). There is a possibility to change the bahaviour
of watchdog reset. Setting WATCHDOG_SD bit enables SHUTDOWN mode, and
clearing it enables POWERDOWN mode on watchdog timeout.

If no DT binding is specified the WATCHDOG_SD bit stays in default
configuration, not breaking behaviour of devices which might depend on
default fuse configuration.

Note: This patch requires that the config register CONFIG_I is
configured as writable in the da9062 multi function device.

Signed-off-by: Andrej Picej <andrej.picej@norik.com>
---
Chnages in v4:
 - move the code to probe function

Changes in v3:
 - no changes

Changes in v2:
 - don't force the "reset" for all da9062-watchdog users, instead add DT
   binding where the behavior can be selected
---
 drivers/watchdog/da9062_wdt.c | 27 +++++++++++++++++++++++++++
 1 file changed, 27 insertions(+)
diff mbox series

Patch

diff --git a/drivers/watchdog/da9062_wdt.c b/drivers/watchdog/da9062_wdt.c
index f02cbd530538..bd85f84b0fd4 100644
--- a/drivers/watchdog/da9062_wdt.c
+++ b/drivers/watchdog/da9062_wdt.c
@@ -195,8 +195,11 @@  static int da9062_wdt_probe(struct platform_device *pdev)
 {
 	struct device *dev = &pdev->dev;
 	unsigned int timeout;
+	unsigned int mask;
 	struct da9062 *chip;
 	struct da9062_watchdog *wdt;
+	int ret;
+	u32 val;
 
 	chip = dev_get_drvdata(dev->parent);
 	if (!chip)
@@ -236,6 +239,30 @@  static int da9062_wdt_probe(struct platform_device *pdev)
 		set_bit(WDOG_HW_RUNNING, &wdt->wdtdev.status);
 	}
 
+	/*
+	 * Configure what happens on watchdog timeout. Can be specified with
+	 * "dlg,wdt-sd" dt-binding (0 -> POWERDOWN, 1 -> SHUTDOWN).
+	 * If "dlg,wdt-sd" dt-binding is NOT set use the default.
+	 */
+	ret = device_property_read_u32(dev, "dlg,wdt-sd", &val);
+	if (!ret) {
+		if (val)
+			/* Use da9062's SHUTDOWN mode */
+			mask = DA9062AA_WATCHDOG_SD_MASK;
+		else
+			/* Use da9062's POWERDOWN mode. */
+			mask = 0x0;
+
+		ret = regmap_update_bits(wdt->hw->regmap,
+						DA9062AA_CONFIG_I,
+						DA9062AA_WATCHDOG_SD_MASK,
+						mask);
+
+		if (ret)
+			dev_err(dev, "failed to set wdt reset mode: %d\n",
+				ret);
+	}
+
 	return devm_watchdog_register_device(dev, &wdt->wdtdev);
 }