diff mbox series

[5.10,31/43] power: bq25890: Enable continuous conversion for ADC at charging

Message ID 20220110071818.393356915@linuxfoundation.org
State New
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman Jan. 10, 2022, 7:23 a.m. UTC
From: Yauhen Kharuzhy <jekhor@gmail.com>

commit 80211be1b9dec04cc2805d3d81e2091ecac289a1 upstream.

Instead of one shot run of ADC at beginning of charging, run continuous
conversion to ensure that all charging-related values are monitored
properly (input voltage, input current, themperature etc.).

Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com>
Reviewed-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
---
 drivers/power/supply/bq25890_charger.c |    4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)
diff mbox series

Patch

--- a/drivers/power/supply/bq25890_charger.c
+++ b/drivers/power/supply/bq25890_charger.c
@@ -581,12 +581,12 @@  static irqreturn_t __bq25890_handle_irq(
 
 	if (!new_state.online && bq->state.online) {	    /* power removed */
 		/* disable ADC */
-		ret = bq25890_field_write(bq, F_CONV_START, 0);
+		ret = bq25890_field_write(bq, F_CONV_RATE, 0);
 		if (ret < 0)
 			goto error;
 	} else if (new_state.online && !bq->state.online) { /* power inserted */
 		/* enable ADC, to have control of charge current/voltage */
-		ret = bq25890_field_write(bq, F_CONV_START, 1);
+		ret = bq25890_field_write(bq, F_CONV_RATE, 1);
 		if (ret < 0)
 			goto error;
 	}