@@ -104,6 +104,18 @@ struct tsens_plat_data data_tsens_v2 = {
.fields = tsens_v2_regfields,
};
+/*
+ * For some tsens v2 controllers, its suggested to monitor the
+ * controller health periodically and in case an issue is detected
+ * to reinit tsens controller via trustzone.
+ */
+struct tsens_plat_data data_tsens_v2_reinit = {
+ .ops = &ops_generic_v2,
+ .feat = &tsens_v2_feat,
+ .needs_reinit_wa = true,
+ .fields = tsens_v2_regfields,
+};
+
/* Kept around for backward compatibility with old msm8996.dtsi */
struct tsens_plat_data data_8996 = {
.num_sensors = 13,
@@ -1138,6 +1138,9 @@ static const struct of_device_id tsens_table[] = {
}, {
.compatible = "qcom,msm8996-tsens",
.data = &data_8996,
+ }, {
+ .compatible = "qcom,sm8150-tsens",
+ .data = &data_tsens_v2_reinit,
}, {
.compatible = "qcom,tsens-v1",
.data = &data_tsens_v1,
@@ -607,6 +607,6 @@ extern struct tsens_plat_data data_8916, data_8939, data_8974, data_9607;
extern struct tsens_plat_data data_tsens_v1, data_8976;
/* TSENS v2 targets */
-extern struct tsens_plat_data data_8996, data_tsens_v2;
+extern struct tsens_plat_data data_8996, data_tsens_v2_reinit, data_tsens_v2;
#endif /* __QCOM_TSENS_H__ */