new file mode 100644
@@ -0,0 +1,137 @@
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/adc/maxim,max34408.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Two- and four-channel current monitors with overcurrent control
+
+maintainers:
+ - Ivan Mikhaylov <fr0st61te@gmail.com>
+
+description: |
+ The MAX34408/MAX34409 are two- and four-channel current monitors that are
+ configured and monitored with a standard I2C/SMBus serial interface. Each
+ unidirectional current sensor offers precision high-side operation with a
+ low full-scale sense voltage. The devices automatically sequence through
+ two or four channels and collect the current-sense samples and average them
+ to reduce the effect of impulse noise. The raw ADC samples are compared to
+ user-programmable digital thresholds to indicate overcurrent conditions.
+ Overcurrent conditions trigger a hardware output to provide an immediate
+ indication to shut down any necessary external circuitry.
+
+ Specifications about the devices can be found at:
+ https://www.analog.com/media/en/technical-documentation/data-sheets/MAX34408-MAX34409.pdf
+
+properties:
+ compatible:
+ enum:
+ - maxim,max34408
+ - maxim,max34409
+
+ "#address-cells":
+ const: 1
+
+ "#size-cells":
+ const: 0
+
+ reg:
+ maxItems: 1
+
+ interrupts:
+ maxItems: 1
+
+ shutdown-gpios:
+ description:
+ Shutdown Output. Open-drain output. This output transitions to high impedance
+ when any of the digital comparator thresholds are exceeded as long as the ENA
+ pin is high.
+ maxItems: 1
+
+ shtdn-enable-gpios:
+ description:
+ SHTDN Enable Input. CMOS digital input. Connect to GND to clear the latch and
+ unconditionally deassert (force low) the SHTDN output and reset the shutdown
+ delay. Connect to VDD to enable normal latch operation of the SHTDN output.
+ maxItems: 1
+
+ vdd-supply: true
+
+required:
+ - compatible
+ - reg
+
+patternProperties:
+ "^channel@[0-3]$":
+ $ref: adc.yaml
+ type: object
+ description:
+ Represents the internal channels of the ADC.
+
+ properties:
+ reg:
+ items:
+ minimum: 0
+ maximum: 3
+
+ maxim,rsense-val-micro-ohms:
+ description:
+ Adjust the Rsense value to monitor higher or lower current levels for
+ input.
+ enum: [250, 500, 1000, 5000, 10000, 50000, 100000, 200000, 500000]
+ default: 1000
+
+ required:
+ - reg
+ - maxim,rsense-val-micro-ohms
+
+ unevaluatedProperties: false
+
+allOf:
+ - if:
+ properties:
+ compatible:
+ contains:
+ const: maxim,max34408
+ then:
+ patternProperties:
+ "^channel@[2-3]$": false
+ "^channel@[0-1]$":
+ properties:
+ reg:
+ minimum: 0
+ maximum: 1
+ else:
+ patternProperties:
+ "^channel@[0-3]$":
+ properties:
+ reg:
+ minimum: 0
+ maximum: 3
+
+additionalProperties: false
+
+examples:
+ - |
+ i2c {
+
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ adc@1e {
+ compatible = "maxim,max34409";
+ reg = <0x1e>;
+
+ #address-cells = <1>;
+ #size-cells = <0>;
+ channel@0 {
+ reg = <0x0>;
+ maxim,rsense-val-micro-ohms = <5000>;
+ };
+
+ channel@1 {
+ reg = <0x1>;
+ maxim,rsense-val-micro-ohms = <10000>;
+ };
+ };
+ };
The hardware binding for i2c current monitoring device with overcurrent control. Signed-off-by: Ivan Mikhaylov <fr0st61te@gmail.com> --- .../bindings/iio/adc/maxim,max34408.yaml | 137 ++++++++++++++++++ 1 file changed, 137 insertions(+) create mode 100644 Documentation/devicetree/bindings/iio/adc/maxim,max34408.yaml