@@ -2,7 +2,7 @@
//
// ALSA SoC Texas Instruments TAS2563/TAS2781 Audio Smart Amplifier
//
-// Copyright (C) 2022 - 2023 Texas Instruments Incorporated
+// Copyright (C) 2022 - 2024 Texas Instruments Incorporated
// https://www.ti.com
//
// The TAS2563/TAS2781 driver implements a flexible and configurable
@@ -414,7 +414,7 @@ static void tasdevice_fw_ready(const struct firmware *fmw,
__func__, tas_priv->cal_binaryname[i]);
}
- tasdevice_prmg_calibdata_load(tas_priv, 0);
+ tasdevice_prmg_load(tas_priv, 0);
tas_priv->cur_prog = 0;
out:
if (tas_priv->fw_state == TASDEVICE_DSP_FW_FAIL) {
Use the API with correct sequence instead of the wrong one. Fixes: ef3bcde75d06 ("ASoc: tas2781: Add tas2781 driver") Signed-off-by: Shenghao Ding <shenghao-ding@ti.com> --- v5: - correct changelog has no much relationship with the patch v4: - Use the the culprit of the bug itself as the fixes tag v3: - No changes. v2: - In the Subject, fixed --> Fix - dsp --> DSP - Add Fixes tag - Changed the copyright year to 2024 in the related files v1: - Download calibrated data after loading the new DSP config params - Call tasdevice_prmg_load instead of tasdevice_prmg_calibdata_load, it is unnecessary to load calibrated data after loading DSP program. Load it after loading DSP config params each time. --- sound/soc/codecs/tas2781-i2c.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)