@@ -17,12 +17,12 @@
#define MAX_DIFF_PERCENT 15
#define CON_MON_LCC_OCCUP_PATH \
- "%s/%s/mon_groups/%s/mon_data/mon_L3_%02d/llc_occupancy"
+ "%s/%s/mon_data/mon_L3_%02d/llc_occupancy"
static int cmt_init(const struct resctrl_val_param *param, int domain_id)
{
sprintf(llc_occup_path, CON_MON_LCC_OCCUP_PATH, RESCTRL_PATH,
- param->ctrlgrp, param->mongrp, domain_id);
+ param->ctrlgrp, domain_id);
return 0;
}
@@ -146,7 +146,6 @@ static int cmt_run_test(const struct resctrl_test *test, const struct user_param
struct resctrl_val_param param = {
.resctrl_val = CMT_STR,
.ctrlgrp = "c1",
- .mongrp = "m1",
.filename = RESULT_FILE_NAME,
.mask = ~(long_mask << n) & long_mask,
.num_of_runs = 0,
The CMT selftest instanciates a monitor group to read LLC occupancy. Since the test also creates a control group, it is unnecessary to create another one for monitoring because control groups already provide monitoring too. Remove the unnecessary monitor group from the CMT selftest. Suggested-by: Reinette Chatre <reinette.chatre@intel.com> Signed-off-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com> -- v4: - New patch --- tools/testing/selftests/resctrl/cmt_test.c | 5 ++--- 1 file changed, 2 insertions(+), 3 deletions(-)