From patchwork Wed Apr 14 05:51:51 2021 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: "Vaittinen, Matti" X-Patchwork-Id: 421170 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org X-Spam-Level: X-Spam-Status: No, score=-13.8 required=3.0 tests=BAYES_00, HEADER_FROM_DIFFERENT_DOMAINS,INCLUDES_CR_TRAILER,INCLUDES_PATCH, MAILING_LIST_MULTI, SPF_HELO_NONE, SPF_PASS autolearn=ham autolearn_force=no version=3.4.0 Received: from mail.kernel.org (mail.kernel.org [198.145.29.99]) by smtp.lore.kernel.org (Postfix) with ESMTP id 6323EC433ED for ; Wed, 14 Apr 2021 05:52:02 +0000 (UTC) Received: from vger.kernel.org (vger.kernel.org [23.128.96.18]) by mail.kernel.org (Postfix) with ESMTP id 399DB613CF for ; Wed, 14 Apr 2021 05:52:02 +0000 (UTC) Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1347653AbhDNFwV (ORCPT ); Wed, 14 Apr 2021 01:52:21 -0400 Received: from mail-lf1-f47.google.com ([209.85.167.47]:33401 "EHLO mail-lf1-f47.google.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1347569AbhDNFwU (ORCPT ); Wed, 14 Apr 2021 01:52:20 -0400 Received: by mail-lf1-f47.google.com with SMTP id w8so22677523lfr.0; Tue, 13 Apr 2021 22:51:58 -0700 (PDT) X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:date:from:to:cc:subject:message-id:references :mime-version:content-disposition:in-reply-to; bh=J7crRi/h8pPP48l770iPX9pdtxPTTqKfvzb9h8aF7ts=; b=DBetRYSAYrvxkeku5Y8FSYJFhmz/yUYModq2GHZ1G5/wzs4xUwCWckUxfq5o/4tVIs lW91Paf5/nCc6SwEvGaj4/ojOHWdN0lsIkOsKU4upJRNbPDVY1wVNAovBKoNeJSxSUIq aD87eZv2+Q6jTANmzbT6qjXI/6lNpvpCuK6YU2M3odlfA0UR2qnMv/Hg4xEujKaPA671 IgdEw7ZsfR+5PIhN4VPJBTZkOORTdgaiq0SmyRZx9IP3BWJnNyDLPirEZLd854ge0A1Q jJIucSK6tyFbUL0gJkERHMH9vfv/HazLO8FbyoPNQPJW30Z/ck2CXmE1yywvN09dpIz3 M/9w== X-Gm-Message-State: AOAM531aTnRkR2ZkDAADMCVTFf6z7fMzXWrm5tS6HxfO8Vn+PljfYc1d Ak0P+u88g+aifISm4g42rFA= X-Google-Smtp-Source: ABdhPJyqTcTw+IiTldrqdYI3IsyT0FSJzQXkDjFfn9L+wdSuHRldsKvDoCL6pJpn7ZLIK315R39BBw== X-Received: by 2002:ac2:4e83:: with SMTP id o3mr13196668lfr.616.1618379518193; Tue, 13 Apr 2021 22:51:58 -0700 (PDT) Received: from localhost.localdomain (dc7vkhyyyyyyyyyyyyydy-3.rev.dnainternet.fi. [2001:14ba:16e2:8300::6]) by smtp.gmail.com with ESMTPSA id h17sm1059001lfu.153.2021.04.13.22.51.57 (version=TLS1_3 cipher=TLS_AES_256_GCM_SHA384 bits=256/256); Tue, 13 Apr 2021 22:51:57 -0700 (PDT) Date: Wed, 14 Apr 2021 08:51:51 +0300 From: Matti Vaittinen To: Matti Vaittinen , Matti Vaittinen Cc: Mark Brown , Kees Cook , Andy Shevchenko , Zhang Rui , Guenter Roeck , "agross@kernel.org" , "devicetree@vger.kernel.org" , linux-power , "linux-kernel@vger.kernel.org" , "linux-renesas-soc@vger.kernel.org" , "linux-arm-msm@vger.kernel.org" , "bjorn.andersson@linaro.org" , "lgirdwood@gmail.com" , "robh+dt@kernel.org" Subject: [PATCH v7 1/9] dt_bindings: Add protection limit properties Message-ID: <169aee95444042a7557e630a028e86f1aed0dd62.1618377272.git.matti.vaittinen@fi.rohmeurope.com> References: MIME-Version: 1.0 Content-Disposition: inline In-Reply-To: Precedence: bulk List-ID: X-Mailing-List: linux-arm-msm@vger.kernel.org Support specifying protection/error/warning limits for regulator over current, over temperature and over/under voltage. Most of the PMICs support only "protection" feature but few setups do also support error/warning level indications. On many ICs most of the protection limits can't actually be set. But for example the ampere limit for over-current protection on ROHM BD9576 can be configured - or feature can be completely disabled. Provide limit setting for all protections/errors for the sake of the completeness and do that using own properties for all so that not all users would need to set all levels when only one or few are supported. Signed-off-by: Matti Vaittinen Reviewed-by: Rob Herring --- No changes since RFC-v2 --- .../bindings/regulator/regulator.yaml | 82 +++++++++++++++++++ 1 file changed, 82 insertions(+) diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml index 6d0bc9cd4040..a6ae9ecae5cc 100644 --- a/Documentation/devicetree/bindings/regulator/regulator.yaml +++ b/Documentation/devicetree/bindings/regulator/regulator.yaml @@ -117,6 +117,88 @@ properties: description: Enable over current protection. type: boolean + regulator-oc-protection-microamp: + description: Set over current protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. + + regulator-oc-error-microamp: + description: Set over current error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested. + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. + + regulator-oc-warn-microamp: + description: Set over current warning limit. This is a limit where hardware + is assumed still to be functional but approaching limit where it gets + damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. + + regulator-ov-protection-microvolt: + description: Set over voltage protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. Limit is given as microvolt offset from + voltage set to regulator. + + regulator-ov-error-microvolt: + description: Set over voltage error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. Limit + is given as microvolt offset from voltage set to regulator. + + regulator-ov-warn-microvolt: + description: Set over voltage warning limit. This is a limit where hardware + is assumed still to be functional but approaching limit where it gets + damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. Limit is given as microvolt + offset from voltage set to regulator. + + regulator-uv-protection-microvolt: + description: Set over under voltage protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. Limit is given as microvolt offset from + voltage set to regulator. + + regulator-uv-error-microvolt: + description: Set under voltage error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. Limit + is given as microvolt offset from voltage set to regulator. + + regulator-uv-warn-microvolt: + description: Set over under voltage warning limit. This is a limit where + hardware is assumed still to be functional but approaching limit where + it gets damaged. Recovery actions should be initiated. Zero can be passed + to disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. Limit is given as microvolt + offset from voltage set to regulator. + + regulator-temp-protection-kelvin: + description: Set over temperature protection limit. This is a limit where + hardware performs emergency shutdown. Zero can be passed to disable + protection and value '1' indicates that protection should be enabled but + limit setting can be omitted. + + regulator-temp-error-kelvin: + description: Set over temperature error limit. This is a limit where part of + the hardware propably is malfunctional and damage prevention is requested + Zero can be passed to disable error detection and value '1' indicates + that detection should be enabled but limit setting can be omitted. + + regulator-temp-warn-kelvin: + description: Set over temperature warning limit. This is a limit where + hardware is assumed still to be functional but approaching limit where it + gets damaged. Recovery actions should be initiated. Zero can be passed to + disable detection and value '1' indicates that detection should + be enabled but limit setting can be omitted. + regulator-active-discharge: description: | tristate, enable/disable active discharge of regulators. The values are: