Message ID | 20220517180911.246016-1-f.fainelli@gmail.com |
---|---|
Headers | show |
Series | MMC timeout back ports | expand |
On Tue, May 17, 2022 at 11:09:08AM -0700, Florian Fainelli wrote: > These 3 commits from upstream allow us to have more fine grained control > over the MMC command timeouts and this solves the following timeouts > that we have seen on our systems across suspend/resume cycles: > > [ 14.907496] usb usb2: root hub lost power or was reset > [ 15.216232] usb 1-1: reset high-speed USB device number 2 using > xhci-hcd > [ 15.485812] bcmgenet 8f00000.ethernet eth0: Link is Down > [ 15.525328] mmc1: error -110 doing runtime resume > [ 15.531864] OOM killer enabled. > > Thanks! > > Ulf Hansson (3): > mmc: core: Specify timeouts for BKOPS and CACHE_FLUSH for eMMC > mmc: block: Use generic_cmd6_time when modifying > INAND_CMD38_ARG_EXT_CSD > mmc: core: Default to generic_cmd6_time as timeout in __mmc_switch() > > drivers/mmc/core/block.c | 6 +++--- > drivers/mmc/core/mmc_ops.c | 25 +++++++++++++------------ > 2 files changed, 16 insertions(+), 15 deletions(-) > > -- > 2.25.1 > All now queued up, thanks! greg k-h