diff mbox series

[5.4,149/191] platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

Message ID 20200107205340.944264324@linuxfoundation.org
State Superseded
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman Jan. 7, 2020, 8:54 p.m. UTC
From: Michael Haener <michael.haener@siemens.com>

commit e8796c6c69d129420ee94a1906b18d86b84644d4 upstream.

The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
 drivers/platform/x86/pmc_atom.c |    8 ++++++++
 1 file changed, 8 insertions(+)
diff mbox series

Patch

--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -429,6 +429,14 @@  static const struct dmi_system_id critcl
 			DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
 		},
 	},
+	{
+		.ident = "CONNECT X300",
+		.matches = {
+			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+			DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
+		},
+	},
+
 	{ /*sentinel*/ }
 };