diff mbox series

[5.5,018/257] hinic: fix wrong para of wait_for_completion_timeout

Message ID 20200416131328.185985326@linuxfoundation.org
State New
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman April 16, 2020, 1:21 p.m. UTC
From: Luo bin <luobin9@huawei.com>

[ Upstream commit 0da7c322f116210ebfdda59c7da663a6fc5e9cc8 ]

the second input parameter of wait_for_completion_timeout should
be jiffies instead of millisecond

Signed-off-by: Luo bin <luobin9@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
---
 drivers/net/ethernet/huawei/hinic/hinic_hw_cmdq.c | 3 ++-
 drivers/net/ethernet/huawei/hinic/hinic_hw_mgmt.c | 5 +++--
 2 files changed, 5 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/drivers/net/ethernet/huawei/hinic/hinic_hw_cmdq.c b/drivers/net/ethernet/huawei/hinic/hinic_hw_cmdq.c
index 33f93cc25193a..5f2d57d1b2d37 100644
--- a/drivers/net/ethernet/huawei/hinic/hinic_hw_cmdq.c
+++ b/drivers/net/ethernet/huawei/hinic/hinic_hw_cmdq.c
@@ -389,7 +389,8 @@  static int cmdq_sync_cmd_direct_resp(struct hinic_cmdq *cmdq,
 
 	spin_unlock_bh(&cmdq->cmdq_lock);
 
-	if (!wait_for_completion_timeout(&done, CMDQ_TIMEOUT)) {
+	if (!wait_for_completion_timeout(&done,
+					 msecs_to_jiffies(CMDQ_TIMEOUT))) {
 		spin_lock_bh(&cmdq->cmdq_lock);
 
 		if (cmdq->errcode[curr_prod_idx] == &errcode)
diff --git a/drivers/net/ethernet/huawei/hinic/hinic_hw_mgmt.c b/drivers/net/ethernet/huawei/hinic/hinic_hw_mgmt.c
index c1a6be6bf6a8c..8995e32dd1c00 100644
--- a/drivers/net/ethernet/huawei/hinic/hinic_hw_mgmt.c
+++ b/drivers/net/ethernet/huawei/hinic/hinic_hw_mgmt.c
@@ -43,7 +43,7 @@ 
 
 #define MSG_NOT_RESP                    0xFFFF
 
-#define MGMT_MSG_TIMEOUT                1000
+#define MGMT_MSG_TIMEOUT                5000
 
 #define mgmt_to_pfhwdev(pf_mgmt)        \
 		container_of(pf_mgmt, struct hinic_pfhwdev, pf_to_mgmt)
@@ -267,7 +267,8 @@  static int msg_to_mgmt_sync(struct hinic_pf_to_mgmt *pf_to_mgmt,
 		goto unlock_sync_msg;
 	}
 
-	if (!wait_for_completion_timeout(recv_done, MGMT_MSG_TIMEOUT)) {
+	if (!wait_for_completion_timeout(recv_done,
+					 msecs_to_jiffies(MGMT_MSG_TIMEOUT))) {
 		dev_err(&pdev->dev, "MGMT timeout, MSG id = %d\n", msg_id);
 		err = -ETIMEDOUT;
 		goto unlock_sync_msg;