diff mbox series

[5.10,023/593] USB: cdc-acm: blacklist Heimann USB Appset device

Message ID 20210712060845.742493111@linuxfoundation.org
State Superseded
Headers show
Series None | expand

Commit Message

Greg Kroah-Hartman July 12, 2021, 6:03 a.m. UTC
From: Hannu Hartikainen <hannu@hrtk.in>

commit 4897807753e078655a78de39ed76044d784f3e63 upstream.

The device (32a7:0000 Heimann Sensor GmbH USB appset demo) claims to be
a CDC-ACM device in its descriptors but in fact is not. If it is run
with echo disabled it returns garbled data, probably due to something
that happens in the TTY layer. And when run with echo enabled (the
default), it will mess up the calibration data of the sensor the first
time any data is sent to the device.

In short, I had a bad time after connecting the sensor and trying to get
it to work. I hope blacklisting it in the cdc-acm driver will save
someone else a bit of trouble.

Signed-off-by: Hannu Hartikainen <hannu@hrtk.in>
Cc: stable <stable@vger.kernel.org>
Link: https://lore.kernel.org/r/20210622141454.337948-1-hannu@hrtk.in
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
 drivers/usb/class/cdc-acm.c |    5 +++++
 1 file changed, 5 insertions(+)
diff mbox series

Patch

--- a/drivers/usb/class/cdc-acm.c
+++ b/drivers/usb/class/cdc-acm.c
@@ -1948,6 +1948,11 @@  static const struct usb_device_id acm_id
 	.driver_info = IGNORE_DEVICE,
 	},
 
+	/* Exclude Heimann Sensor GmbH USB appset demo */
+	{ USB_DEVICE(0x32a7, 0x0000),
+	.driver_info = IGNORE_DEVICE,
+	},
+
 	/* control interfaces without any protocol set */
 	{ USB_INTERFACE_INFO(USB_CLASS_COMM, USB_CDC_SUBCLASS_ACM,
 		USB_CDC_PROTO_NONE) },