Viresh Kumar May 25, 2018, 10:31 a.m. UTC
The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>

---
 arch/arm/boot/dts/rk322x.dtsi | 3 +++
 1 file changed, 3 insertions(+)

-- 
2.15.0.194.g9af6a3dea062
diff mbox series

Patch

diff --git a/arch/arm/boot/dts/rk322x.dtsi b/arch/arm/boot/dts/rk322x.dtsi
index be80e9a2c9af..ef414e39bf3a 100644
--- a/arch/arm/boot/dts/rk322x.dtsi
+++ b/arch/arm/boot/dts/rk322x.dtsi
@@ -80,6 +80,7 @@ 
 			reg = <0xf01>;
 			resets = <&cru SRST_CORE1>;
 			operating-points-v2 = <&cpu0_opp_table>;
+			#cooling-cells = <2>; /* min followed by max */
 			enable-method = "psci";
 		};
 
@@ -89,6 +90,7 @@ 
 			reg = <0xf02>;
 			resets = <&cru SRST_CORE2>;
 			operating-points-v2 = <&cpu0_opp_table>;
+			#cooling-cells = <2>; /* min followed by max */
 			enable-method = "psci";
 		};
 
@@ -98,6 +100,7 @@ 
 			reg = <0xf03>;
 			resets = <&cru SRST_CORE3>;
 			operating-points-v2 = <&cpu0_opp_table>;
+			#cooling-cells = <2>; /* min followed by max */
 			enable-method = "psci";
 		};
 	};