@@ -80,6 +80,7 @@
reg = <0xf01>;
resets = <&cru SRST_CORE1>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
@@ -89,6 +90,7 @@
reg = <0xf02>;
resets = <&cru SRST_CORE2>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
@@ -98,6 +100,7 @@
reg = <0xf03>;
resets = <&cru SRST_CORE3>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
};
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> --- arch/arm/boot/dts/rk322x.dtsi | 3 +++ 1 file changed, 3 insertions(+) -- 2.15.0.194.g9af6a3dea062