@@ -1580,11 +1580,6 @@ static int sysc_reset(struct sysc *ddata)
static int sysc_init_module(struct sysc *ddata)
{
int error = 0;
- bool manage_clocks = true;
-
- if (ddata->cfg.quirks &
- (SYSC_QUIRK_NO_IDLE | SYSC_QUIRK_NO_IDLE_ON_INIT))
- manage_clocks = false;
error = sysc_clockdomain_init(ddata);
if (error)
@@ -1617,28 +1612,32 @@ static int sysc_init_module(struct sysc *ddata)
if (ddata->legacy_mode) {
error = sysc_legacy_init(ddata);
if (error)
- goto err_main_clocks;
+ goto err_reset;
}
if (!ddata->legacy_mode) {
error = sysc_enable_module(ddata->dev);
if (error)
- goto err_main_clocks;
+ goto err_reset;
}
error = sysc_reset(ddata);
if (error)
dev_err(ddata->dev, "Reset failed with %d\n", error);
- if (!ddata->legacy_mode && manage_clocks)
+ if (error && !ddata->legacy_mode)
sysc_disable_module(ddata->dev);
+err_reset:
+ if (error && !(ddata->cfg.quirks & SYSC_QUIRK_NO_RESET_ON_INIT))
+ reset_control_assert(ddata->rsts);
+
err_main_clocks:
- if (manage_clocks)
+ if (error)
sysc_disable_main_clocks(ddata);
err_opt_clocks:
/* No re-enable of clockdomain autoidle to prevent module autoidle */
- if (manage_clocks) {
+ if (error) {
sysc_disable_opt_clocks(ddata);
sysc_clkdm_allow_idle(ddata);
}
@@ -2411,9 +2410,16 @@ static int sysc_probe(struct platform_device *pdev)
goto unprepare;
}
- /* Balance reset counts */
- if (ddata->rsts)
- reset_control_assert(ddata->rsts);
+ /* Balance use counts as PM runtime should have enabled these all */
+ if (!(ddata->cfg.quirks & SYSC_QUIRK_NO_RESET_ON_INIT))
+ reset_control_assert(ddata->rsts);
+
+ if (!(ddata->cfg.quirks &
+ (SYSC_QUIRK_NO_IDLE | SYSC_QUIRK_NO_IDLE_ON_INIT))) {
+ sysc_disable_main_clocks(ddata);
+ sysc_disable_opt_clocks(ddata);
+ sysc_clkdm_allow_idle(ddata);
+ }
sysc_show_registers(ddata);
Current implementation for ti-sysc powers down the module once module init is complete. However, right after power is disabled, it is enabled via runtime PM. This is unnecessary so avoid it by re-ordering the events a bit; move powering down of the module post runtime PM enable which makes sure the use counts are maintained properly and there is no extra power down/up sequence for the module. Signed-off-by: Tero Kristo <t-kristo@ti.com> --- drivers/bus/ti-sysc.c | 32 +++++++++++++++++++------------- 1 file changed, 19 insertions(+), 13 deletions(-) -- 2.17.1 -- Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki